What is a "Unit Reconfiguration Issue" Alert?
Unit Reconfiguration Issue alerts are provided to notify when one or more Brilliant devices in a unit are taking longer than expected to reconfigure during a Unit Reconfiguration following a move in or move out.
In particular, Unit Reconfiguration Issues are triggered if the unit reconfiguration process has not completed 30 minutes after being initiated. Normally, a unit reconfiguration should only take between 5-10 minutes.
How do Unit Reconfiguration Issue Alerts work?
When a Unit Reconfiguration Issue alert is active for a unit in Brilliant, you will see the following:
- Unit Reconfiguration Issue Alert
- Access this alert by clicking on the bell icon in the top right corner.
- Tap on the alert to see more details.
- Unit Reconfiguration Issue Alert Tag
- An alert tag will be shown on the page listing all units for a given property.
- An alert tag will be shown on the page that shows the details for a specific unit.
- Unit Reconfiguration Issue Banner
- A banner will be displayed on the page that shows the details for a specific unit.
- Tap on the banner to see more details.
- Unit Reconfiguration Issue Notification (if enabled)
- A Unit Reconfiguration Issue notification will be sent via email and/or text to all Admins of your Brilliant Command Center organization that have this type of notification enabled.
How do I resolve a Unit Reconfiguration Issue Alert?
If a unit has an active Unit Reconfiguration Issue alert, one of the below issues may be occurring:
The Brilliant Control(s) in the unit were offline when the Unit Reconfiguration began.
In this case, the following may be causing this issue:
- The wrong Backup WiFi Network is set for the unit on the Brilliant Command Center. To resolve this issue:
- First, set the correct Backup WiFi network for the unit on the Brilliant Command Center.
- After completing step 1, manually connect the unit's Brilliant Control(s) to the correct Backup WiFi network by going to Settings > Connectivity.
- There is an issue with the unit's Backup WiFi Network (such as a network outage). To resolve this issue:
- Resolve the issue with the unit's Backup WiFi Network.
- Once the Backup WiFi Network is working properly, the unit's Brilliant Control(s) will automatically connect and resume the Unit Reconfiguration process.
The Brilliant Control(s) in the unit were online when Unit Reconfiguration began, but failed to re-connect to the unit's Backup WiFi during the reconfiguration process.
In this case, the following may be causing this issue:
- The wrong Backup WiFi Network is set for the unit on the Brilliant Command Center. To resolve this issue:
- Connect the unit's Brilliant Controls to an any available WiFi network.
- If the unit's Brilliant Controls do not automatically resume reconfiguration, then reboot the Controls by either Navigating to Settings > Restart Control or detaching and reattaching the Control's faceplate.
- After the unit's Brilliant Controls have finished reconfiguring, set the correct Backup WiFi network for the unit on the Brilliant Command Center.
- There is an issue with the unit's Backup WiFi Network (such as a network outage). To resolve this issue:
- Resolve the issue with the unit's Backup WiFi Network.
- If the unit's Brilliant Controls do not automatically resume reconfiguration, then reboot the Controls by either Navigating to Settings > Restart Control or detaching and reattaching the Control's faceplate.
There is an unknown issue preventing the Brilliant Control(s) from starting or completing the reconfiguration process.
- In this case, try restarting the unit's Brilliant Controls by either Navigating to Settings > Restart Control or detaching and reattaching the Control's faceplate.
- If this does not resolve the issue, then please contact Brilliant support.
NOTE: It may take up to 10 minutes for the alert to stop showing on the Brilliant Command Center after resolving the issue. If you have Unit Reconfiguration Issue notifications enabled for your Brilliant Admin account, you will receive an "Reconfiguration Issue Resolved" notification after resolving the issue.